JACoW logo

Joint Accelerator Conferences Website

The Joint Accelerator Conferences Website (JACoW) is an international collaboration that publishes the proceedings of accelerator conferences held around the world.


RIS citation export for WEPMY033: Intermediate Commissioning Results of the 70 mA/50 keV H⁺ and 140 mA/100 keV D⁺ ECR Injector of IFMIF/LIPAC

TY - CONF
AU - Bolzon, B.
AU - Ayala, J.M.
AU - Beauvais, P.-Y.
AU - Bellan, L.
AU - Cara, P.
AU - Chauvin, N.
AU - Chel, S.
AU - Comunian, M.
AU - Dzitko, H.
AU - Fagotti, E.
AU - Gex, D.
AU - Gobin, R.
AU - Grespan, F.
AU - Harrault, F.
AU - Heidinger, R.
AU - Ichimiya, R.
AU - Ihara, A.
AU - Ikeda, Y.
AU - Kasugai, A.
AU - Kikuchi, T.
AU - Kitano, T.
AU - Knaster, J.
AU - Komata, M.
AU - Kondo, K.
AU - Maebara, S.
AU - Marqueta, A.
AU - Nishiyama, K.
AU - O'hira, S.
AU - Okumura, Y.
AU - Perez, M.
AU - Phillips, G.
AU - Pisent, A.
AU - Pruneri, G.
AU - Sakamoto, K.
AU - Scantamburlo, F.
AU - Senée, F.
AU - Shinto, K.
AU - Sugimoto, M.
AU - Takahashi, H.
AU - Usami, H.
AU - Valette, M.
ED - Petit-Jean-Genaz, Christine
ED - Kim, Dong Eon
ED - Kim, Kyung Sook
ED - Ko, In Soo
ED - Schaa, Volker RW
TI - Intermediate Commissioning Results of the 70 mA/50 keV H⁺ and 140 mA/100 keV D⁺ ECR Injector of IFMIF/LIPAC
J2 - Proc. of IPAC2016, Busan, Korea, May 8-13, 2016
C1 - Busan, Korea
T2 - International Particle Accelerator Conference
T3 - 7
LA - english
AB - The LIPAc accelerator aims to operate 125 mA/CW deuteron beam at 9 MeV to validate IFMIF's accelerators that will operate in CW 125 mA at 40 MeV. The different subsystems of LIPAc have been designed and constructed mainly by European labs and are being installed and commissioned in Rokkasho Fusion Center. The 2.45 GHz ECR injector developed by CEA-Saclay is designed to deliver 140 mA/100 keV CW D⁺ beam with 99% gas fraction ratio. Its LEBT presents a dual solenoid focusing system to transport and match the beam into the RFQ. Its commissioning continues in 2016 in parallel with the RFQ installation. The normalized RMS emittance at the RFQ injection cone is to be within 0.25π mm·mrad to allow 96% transmission through the 9.81 m long RFQ. In order to avoid activation during commissioning, an equal perveance H⁺ beam of half current and half energy as nominal with deuterons is used. In this article, the commissioning results with 110 mA/100 keV D⁺ beam and 55 mA/50 keV H⁺ beam are first reported.
PB - JACoW
CP - Geneva, Switzerland
SP - 2625
EP - 2627
KW - emittance
KW - rfq
KW - operation
KW - focusing
KW - solenoid
DA - 2016/06
PY - 2016
SN - 978-3-95450-147-2
DO - 10.18429/JACoW-IPAC2016-WEPMY033
UR - http://jacow.org/ipac2016/papers/wepmy033.pdf
ER -